Takagi.ca

(416) 402-8295 Takagi tankless repair parts installation service.

Takagi Tankless models.

A hot water tap is opened...
The water enters the heater.
A water flow sensor detects the water flow.
The computer automatically ignites the burner.
The water circulates through the tankless water heat exchanger (coil).
The heat exchanger instantly heats the water
at the designated temperature. (this takes only 5 seconds)
The heater can provide you with endless hot water continuously. Check (Toronto) incoming water temperatures.
No more running out of hot water in the middle of a shower!
When the hot water tap is turned off, the unit shuts down this tank less automatically.
                                               

                                                              

           

We are contractors that supply install and service tankless Takagi Water heaters Serving Montreal, Oakville, Toronto, Etobicoke, Brampton, Burlington

 

           
Meet the pioneer of tankless water heaters. The T-K2 Tankless doesn't store hot water. It generates hot water on demand - saving time, money and space. The thermal efficiency of the Flash T-K2 Tankless heater is over 85% using natural gas and 86% on propane gas with low Nox emission to meet AQMD (Air Quality Management District) regulation. This is far superior to the conventional boiler water heater efficiency. Because the T-K2 is more efficient, it uses less fuel and is therefore more cost efficient to operate and environmentally friendly. 

 

Natural Gas Input Min. 20,000 Btu Max. 185,000 Btu
LPG Input Min. 19,000 Btu Max. 175,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 11" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.3" WC Propane 2.5" WC
Weight 60 lbs.
Dimensions 24.5" x 16.5" x 8.3"
Ignition Electronic Ignition
Electrical Supply AC 120 V

 

   
T-KD20
uses a "Direct Vent System". With a three-inch round combustible air intake vent and four-inch round exhaust power vent, FLASH T-KD20 is designed to work when indoor combustion air is not available - making it the perfect system for climate -controlled environments such as colder areas.
 
 


 

Technical Specification
 
 
Natural Gas Input Min. 20,000 Btu Max. 185,000 Btu
LPG Input Min. 19,000 Btu Max. 175,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.3" WC Propane 2.5" WC
Weight 60 lbs.
Dimensions 24.5" x 16.5" x 8.3"
Ignition Electronic Ignition
Electrical Supply AC 120 V

Specifications may change without prior notice. Contact our Montreal tankless dealer office for more details on our heaters.
 

We are licensed gas fitters and are dealers for Takagi  tankless in Ontario.

   
At just twenty inches high, and weighing only fourty pounds, the T-K Jr. is the most compact unit in the Takagi line. Designed to produce endless hot water and radiant heating for smaller homes, The T-K Jr. uses the same innovative technology as the original Takagi units - only on an even smaller scale. Toronto dealers of tankless water heaters.
 
 


We are contractors that supply install and service Takagi Water heaters in Ontario & Quebec Canada.

Technical Specification
 
Below find specifications on Takagi tank less in Canada.
Natural Gas Input Min. 19,500 Btu Max. 140,000 Btu
LPG Input Min. 17,000 Btu Max. 140,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.8" WC Propane 3.2" WC
Weight 30 lbs., this heater is light weight.
Dimensions 20" x 14" x 6"
tankless Ignition Electronic Ignition
Electrical Supply AC 120 V

Specifications may change without prior notice. These water heaters change from day to day as they improve their installations procedures and improvements of water heating systems..

 

Serving Montreal, Oakville, Toronto, Etobicoke, Brampton, Burlington

 

    FLASH T-K1S Tankless Water Heater

Much lighter (45 lbs) and more benefits!
Now Available !

Takagi's latest model , Flash T-K1S, is energy efficient and environmentally friendly.

At just two-and-a half feet high, Flash T-K1S generates hot water as needed using just 2.2 cubic feet of space. Weighing in at only 45 pounds and with a first-hour flow rate of over 240 gallons, this compact model produces endless hot water long after conventional units have run cold. Wall-mounted inside or outside, the T-K1S provides 190,000 BTUs of continuous heat, while offering thermal efficiency of 85% using natural gas and 87% with propane.

WITHOUT the remote controller, Temperature can be adjusted as low as 113F, up to 182F, which makes it perfect for floor heating applications. Talk to our dealers for more info on these fast recovery tankless units.
 

 

Free estimates for Takagi Tankless water Heaters
 

Technical Specifications
 
 
Natural Gas Input Min. 15,000 Btu Max. 190,000 Btu
LPG Input Min. 17,000 Btu Max. 190,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.6" WC Propane 3.4" WC
Weight 45 lbs.
Dimensions 24" x 16.5" x 8"

Specifications may change without prior notice.
 

We carry parts for Takagi Water heaters Montreal office 1550 Metcalfe Dr Unit A Park Royal Plaza 514 316 1802

 

 

   
Meet the newest member of Takagi Tankless water heater family. With 95%* energy efficiency, the T-H1 is the most technologically advanced water heater on the instantaneous water heater market today. The new T-H1 is equipped with a Pre-Heating system and Built in Neutralizer that provides greater efficiency and reliability. Discover the future, discover the Flash T-H1.

Designed for commercial and heavy residential use.
 

 

A proud member of Homepros.ca
 

Technical Specifications
 
 
Natural Gas Input Min. 15,000 Btu Max. 199,000 Btu
LPG Input Min. 18,000 Btu Max. 190,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.3" WC Propane 2.5" WC
Weight 90 lbs.
Dimensions 28.5" x 19" x 12"
Ignition Electronic Ignition
Electrical Supply AC 120 V

Specifications may change without prior notice

Installing contractors in your area

 

 

 
A unique feature of the MOBIUS T-M1 is its flexibility in large use applications such as big homes, hotels and motels, apartments and other commercial structures. Up to 20 units can be linked together using a single main control system. When installed in this manner, MOBIUS units can replace the space consuming, inefficient boilers used in most large buildings. Further, the use of MOBIUS units allows the building owners to customize the water heating system by using the correct number of units to meet the building's hot water needs. When you are using a MOBIUS multi-system, you don't have to burn a million BTU for one application - just burn as much as you need.
 
 


Call Allan Thorne for an in home estimate 514 316 1802

Technical Specifications
 
 
Natural Gas Input Min. 25,000 Btu Max. 235,000 Btu
LPG Input Min. 25,000 Btu Max. 225,000 Btu
Gas Connection 3/4" NPT
Water Connections 3/4" NPT
Water Pressure Min. 15 psi Max. 150 psi
Natural Gas Pressure Inlet Min. 5" WC Max. 10.5" WC
LP Gas Pressure Inlet Min. 11" WC Max. 14" WC
Manifold Pressure Natural 2.2" WC Propane 2.7" WC
Weight 70 lbs.
Dimensions 24" x 18" x 9"

Specifications may change without prior notice.
 

Start saving gas today with Takagi Tankless

TK-BK01 TK-TV01 TK-TV03
Wall Mounting
Brackets
Wall Ventilation
Terminator
Exhaust Backflow
Prevention Kit
For wall mounting installation. Wall vent terminator for installation of Takagi water heaters to be vented out a side wall. Prevents cold air from entering vent and causing heat exchnager to freeze.
 


 

TK-TV04 TK-TV05 TM-TV06
Outside Installation
Venting Cap
Wall Ventilation
Terminator
Outside Installation
Venting Cap
Vent cap kit provides for outside installation of Flash T-K2 water heater. Wall Ventilation Terminator (for T-KD20): Wall vent terminator for installation of Flash T-KD20 tove vented out a side wall. Vent cap kit provides for outside installation of Mobius T-M1 water heater.


 

TK-RE01 TM-RE10 TK-RE02
Temparature Remote
Controller
Temparature Remote
Controller
Temparature Remote
Controller
It allows output temperatures beyond the factory settings and also shows error codes for problems that might develop.

(95, 100, 102, 104, 106, 108, 110, 111, 113, 115, 117, 122, 131, 140, 158, 167F)
It allows output temperatures beyond the factory settings and also shows error codes for problems that might develop.

(95, 100, 102, 104, 106, 108, 110, 111, 113, 115, 117, 122, 131, 140, 158, 167, 176F)
It allows output temperatures beyond the factory settings shows error codes, and monitors incoming and outgoing water temperatures.

(95, 100, 102, 104, 106, 108, 110, 111, 113, 115, 117, 122, 131, 140, 158, 167F)
     
TM-RE20    
Multiple Unit
Controller
   
Mobius multi-unit controller allows for computer monitoring and control of multiple unit installations of Mobius water heaters.    



 

Model FLASH T-K2 FLASH T-KD20 FLASH T-KJr. FLASH T-K1S MOBIUS T-M1
TK-BK01 Equipped Equipped
TK-RE01 -
TK-RE02 -
TK-TV01 -
TK-TV03
TK-TV04 - -
TK-TV05 - - - -
TM-TV06 - - - -
TM-RE10 - - - -
TM-RE20 - - - -
   = Can be used with that unit

 

 

Model

FLASH T-K Jr.

FLASH T-KD20

FLASH T-K2

FLASH T-K1S

MOBIUS T-M1

BTU Max (NG)

140,000 BTU

185,000 BTU 

185,000 BTU

190,000 BTU 

235,000 BTU

BTU Min (NG)

19,500 BTU

20,000 BTU 

20,000 BTU

15,000 BTU 

25,000 BTU

Flow Rating
0.75 - 5.8 GPM
0.75 - 6.9 GPM
0.75 - 6.9 GPM
0.75 - 7.2 GPM
0.75 - 9.6 GPM

First Hour
Rating
(DOE)

181 gallons/hour
3.0 gallons/minute
(77F rising)

240 gallons/hour
4.0 gallons/minute
(77F rising)

240 gallons/hour
4.0 gallons/minute
(77F rising)

245 gallons/hour
4.1 gallons/minute
(77F rising)

300 gallons/hour
5.0 gallons/minute
(77F rising)

Net Weight

 30 lbs

 60 lbs

60lbs.

46lbs.

70lbs.

Energy Factor

NG 83
LP 84

NG 84
LP 85

NG 84
LP 85

NG 83
LP 84

NG 82
LP 84

Dimensions

H20.0" W14.0" D6.0"

H24.0" W18.0" D9.0"

H24.0" W18.0" D9.0"

H24.5" W16.5" D8.3"

H24.0" W18.0" D9.0"

Thermal
Efficiency

Natural: 83.0%
LP: 84.0 %

Natural: 85.0%
LP: 86.0 %

Natural: 85.0%
LP: 86.0 %

Natural: 83.0%
LP: 84.0 %

Natural: 82.3 %
LP: 84.7 %

 


 

   

Model

FLASH T- H1

BTU Max (NG)

199,000 BTU

BTU Min (NG)

15,000 BTU

Flow Rating
0.75 - 10.5 GPM

First Hour
Rating
(DOE)

285 gallons/hour
4.75 gallons/minute
(77F rising)

Net Weight

90 lbs

Energy Factor

NG 92
LP
94

Dimensions

H28.5" W19.0" D12.0"

Thermal
Efficiency

Natural: 92.0%
LP: 95.0 %

TROUBLESHOOTING GUIDES


T-K3-PRO (LP) T-K3-SP (LP) T-D2-IN (LP) T-M32-ASME (LP) T-D2-OS (LP) T-K3-OS (NG) T-M32 (LP) T-K4-OS (NG) T-H2-OS (LP) T-D2-IN (NG) T-K3-SP (NG) T-H2S-OS (NG) T-M50 (NG) T-H2S-DV (NG) T-K4-OS (LP) T-D2-OS (NG) T-H2-OS (NG) T-K4-IN (NG) T-K3-PRO (NG) T-H2-DV (LP) T-M32-ASME (NG) T-M50-ASME (LP) T-M32 (NG) T-M50-ASME (NG) T-K3-OS (LP) T-M50 (LP) T-K3 (NG) T-K3 (LP) T-K4-IN (LP) T-H2S-DV (LP) T-H2-DV (NG) T-H2S-OS (LP) Canada.